  Consolidated Technology Industrial - Metal Sheath Vat Heaters  
 

Protection

It is essential that the solution level covers the heated portion of the element at all times otherwise element overheating will occur. The use of LOW LIQUID LEVEL CUT-OUT is advised, particularly where tanks are made of, or lined with plastic.

Before removing heaters from a tank, they should be switched off and electrically isolated and remain immersed for a suitable period to ensure no undue temperature rise that may contribute to permanent failure.

Metal sheathed and Teflon coated heaters must be effectively earthed and be installed in accordance to current IEE wiring regulations for electrical installations.

To provide enhanced operator protection, it is recommended that a suitable residual current device with rated tripping current of 30mA or less be incorporated in the supply to the heater.

Further guidance on the installation and use of immersion heaters is available in the BNCE 'Safety Guidelines for Industrial Electric Immersion Heaters'.

To discuss your requirements further or to obtain further information please contact us direct on:
Tel: 01733 558777   Fax: 01733 558789   Mobile: 07860 776633  E-mail:
industrial@ctlimited.co.uk

 
Sheath KW Heated Length

Overall Length

Price
    Inches mm Inches mm £
Mild Steel 2 15 381 24 610 73.00
  3 18 457 30 762 73.00
  4 24 610 36 914 77.00
  6

36

914 48 1219 81.00
             
Titanium 2 15 381 24 610 152.00
  3 18 457 30 762 159.00
  4 24 610 36 914 177.00
  6 36 914 48 1219 232.00
             
Stainless Steel 2 15 381 24 610 105.00
  3 18 457 30 762 110.00
  4 24 610 36 914 117.00
  6 36 914 48 1219 137.00